Loading...
071 PAGGI&MARTIN Consulting Engineers & Land Surveyors 07/ . 54-56 Main Street Poughkeepsie, New York 12601 914-471-7898 914-471-0905 (FAX) November 21, 1997 Town Board Town of Wappinger P.O. Box 324 Wappingers Falls, New York 12590 Attention: Constance O. Smith, Supervisor Reference: ADA Handicap Accessible Entry Doors/Town Hall Dear Supervisor Smith & Board Members: As per your direction, this office has investigated the costs associated with retro-fitting an automatic opening handicap accessible door at the Town Hall building. Our investigation has revealed that the preferred method of providing automatic opening handicap accessible entry to the building would be via the existing front (north) entry way. Door system component part prices were obtained from Mr. Jeff Dobos, Door Control, Inc., 67 South Turnpike Road, Wallingford, Connecticut 06492 The proposed handicap accessible entry system would include dual sliding doors constructed of aluminum and glass to match existing, mat activated automatic door openers, electric service, demolition and retro-fitting, and a new 5' wide concrete entry sidewalk and drop curb. We have prepared an estimated project cost, broken down as follows: I ITEM II COST I o Horton Automatic 2310 Bi-Parting Sliding $ 10,000.00 Door with Controls 0 Provide Electric Service to Door Opener $ 2,000.00 0 Demo of Existing & Retro-fit of New Door $ 3,000.00 0 Excavate 5"W x 70' L Section of Existing $ 1,000.00 Pavers at Entry Way 0 Place New 5'W x 70'L Concrete Entry Walk $ 1,750.00 o New Concrete Entry Ram & Drop Curb $ 1,250.00 Construction Subtotal $ 19,000.00 + 10% contingencies $ 1,900.00 Construction Total $ 20,900.00 + 20% Fees (Engineering Design, $ 4,100.00 Inspection, Administrative) I TOTAL ESTIMATED PROJECT COST II $ 25,000.001 Joseph E. Paggi, Jr., P.E. Ernst Martin,Jr., P.E., 1.5. @ printed on recycled paper Constance O. Smith - 2- Town Board RE: ADA Handicap Accessible Entry Doors November 21, 1997 It should be noted that we also investigated providing access via the existing side (east or west) entry ways. It is our opinion that retro-fitting these side entry ways is a less attractive option due to the fact that the resulting minimum clear openings would approach or equal ADA minimum requirements, and that utilizing these access points would provide no appreciable cost savings over the front entry option. Enclosed for your use is manufacturer's information provided by Door Controls, Inc. If you have any questions or comments, please feel free to contact this office. Thank you for your consideration in this matter. Very truly yours, JP:law Enclosure cc: Hon. June Visconti, Councilperson Hon. Vincent Bettina, Council person Hon. Joseph Ruggiero, Councilperson Hon. Robert Valdati, Council person Albert P. Roberts, Esq. Elaine Snowden Ann Buckley Door Control, Inc. Automatic Pedestrian Doors · Sales and Service FAX TRANSMISSION DATE: 11/24/97 TO: Pete Paggi COMPANY: paggi & Hartin Engineers PAX NUKBER: 914-471-0905 FROH: Jeff Dobos SUBJECT: Biparting Slider Information Please find attached ( ) page(s), including this cover sheet. If all pages are not received, please call for re-transmission. COMMENT: See enclosed documents. If you require any further information please contact me at your earliest convenience. TOLL FREE PHONB #:800-982-6807 TOLL FREE PAX I: 800-330-6906 67 SOUTH TURNPIKE ROAD WALLINGFORD. CT 06492 (203) 269.8282 1972 - Where Quality Is Automatic. 1997 . FAX (203) 265-4979 rTW Honon 4242 Baldwin Boulevard Corpus Christi, Texas 78405-3399 512-888-5591 800-531-3111 Fax: 512-888-6510 Fax: 800-531-3108 http://www.hortondoors.com [Q)[?d~ Wt7~[M@~ AUTOMATIC SLIDING DOORS SERIES 2000 LINEAR DRIVE TYPE: 2310 SO-SX, SX-SO AUTOMATICS A2,14 5/97 I r t ~ '~ Power -t - Supply- " Unit Width Unit Width Optional Muntin Bar SO ~ng Panel so Swing panf' / Safety Be8ms al 24' (610) & 46' (1219) Above Finished Floor 5112'1 r;1 Br8akOut~ (140) ~ fMaldmum Slide 3112' Opening (89) __ n _____" )--<.-~ :::: /.''''", r Eme~ Bl1IakoUlJ BreakOUl;.l rs 112' Maximum SI~lde r- (140) Opening 3 112' __ (89) \ 1";;' "r( .-/ .-/0 ~ Emergencye;;aktlu! ELEV A liON I PLAN TYPE SO.$X & SX.SO SCAl.E: 114' a 1'.0' (1:50) 1'.0' (2134) UNIT SHOWN 3 Standard Package Sizes STANDARD UNIT SIZE MAXIMUM ROUGH OPENING WfDTH HEIGHT" SLIDE OPENING WIDTH HEIGH'll BREAKOUT 7'.0' (2134) T.6' (2286) 36' (914) 7'.0112' (214b) 7'.6 114'(2292) 75' 1905 8'.0' (2438) 7'.6' (2286) 42' (1067) 8'.0 1/2' (24511 7'.6 114'(2292) 87' 2210 . 8'.6' (2591) 7'.6' (2266) 45' (1143) 8'.6 112' (2604) 7'.6 1/4 '(2292) 93' 2362 9'.0' (2743) 7'.6' (2286) 48' (1219) 9'.0 112' (2756) 7'.61/4'(2292) gg' 2515 Opening Heighl = 7'.0' (2134) 'Special UnM Heighllo 8'.0' (2438) SEe SHEET A8.0 THRU A8.7 FOR OPTIONS & DETAILS '~)ll' ,~'14..(6) Shim I ---r I ~ Rough Opening Unit Width C351 PIvol Emergency Breakoul J .... .... JI Exterior 114' (6) Shim n 1 i - {jJ ~ - ~ ~ ~ - ~ ~ f., f., lo~ SERIES 2000 Automatic Sliding Door Operator l Inlerior Side ;! SECTION TYPE SO.SX SCALE: 3' -1'.0' (1:4) Door Shown in Open Position -FOR ALTERNATE THRESHOLD CONDITIONS SEE SHEET A8.2 o SECTION TYPE SO.SX Shown, SX.SO Opposite SCALE: 3' . 1'.0' (1:4) @ Honan AUlomatlcs r888M1S the right to Improve the product and changa ~s speciflcallOns withoul notiee. 0lm8l1l10fll given In U.S. IncheIlollowed by MlIllmetenl on paren1he8ls. .- ~ Horton 4242 Baldwin Boulevard Corpus Christi, Texas 78405-3399 512-888-5591 800-531-3111 Fax: 512-888-6510 Fax: 800-531-3108 http://www.hortondoors.com [Q)[g1~ \wO[M@~ AUTOMATIC SLIDING DOORS SERIES 2000 LINEAR DRIVE TYPE: 2310 SO-SX-SX-SO A2.15 'UTDMATles 5/97 - VI Un~ Width i_power Supply I r f .~ :J Optional Muntin Bar SERIES 2000 Automatic Sliding Door Operator Safety Beams at 24 (610) & 48' (1219) Above Finished Floor C314 CD Imerlor SIdt f"1 r n "'- Breakout Maximum Slide 3112'--11' Opening r11--3112' (89) 1.- __ I (89) \j~ ...... ..." "i'" ..." ..." """"-1' "'- J ........... /\ /"" \ ------ - ......... ~ - . EmargGf"!C\' Breakout rS1/2' (140) n ------ ELEV A TION I PLAN TYPE SO-SX.SX-SO C) SCALE: 1/4' .. 1'.()' (1 :50) 14'.0' (4267) UNIT SHOWN Standard Package Sizes ;~ STANDARD UNIT SIZE MAXIMUM ROUGH OPENING BREAKOUT WIDTH HeiGHT" SLIDE OPENING WIDTH HEIG HT" 8'.0' (2438) 7'.6' (2286) 38' (914) 8'.0112' (2451) 7'.61/4' (2292) 811/2' 2070 9'-0' (2743) 7'.6' (2266) "' """ 9'-0 112' (2756) 7'-6 1/4' (2292) 931/2' 2375 10-0' (3048) 7'.6' (2286) '" 04 " 10'-0112' (3061) 7'.6 1/4' (3061) 1051/2' 2680 12'.0' (3858) 7'.6' (2286) 60' 1524 12'.0112' (3670) 7'.6 1/4' (2292) 129112' 3289 14'.0' (4267) 7'.6' (2286) fi! ltli!lj 14'.0 112' (4280) 7'-6 1/4' (2292) 1 53 1/2' 3899 16'.()' (48771 7'-6' (2266) '" . 'W. 16'.() 112' (4889) 7'-6 1/4' (2292) 177 112' 4509 ,,,. .)~i Shim Rough Opening Unit Widlh seCTION TYPE SO.SX.SX-SO I'f\ SCALE: 3' = 1'.0' (1:4) \:..J Door Shown in Open f>C)ljtlon .FOR AL TERNA TE THRESHOLD CONDITIONS SEE SHEET AU l'~J 1 Opening Height = 7'.0' (2134) 'Speda' Unn Height to 8'-0' (2438) SEe SHEET A8.0 THRU A8.7 FOR OPTIONS & eEl AILS I \ .... .... I \ " " ob"' 'i' ",.,.,.(; ",.".\, ~ ,. ','" "; Safely Beam ~ ~ 1 -.J C351 .... I ........ I " Exterior \ \ ".'" L Emergency Breakout v SECTION TYPE SO.SX.SX-SO SCALE: 3'.1'.0' (1:4) o Horton Automatics reserves the right to Improv.lhI product and chang- 4S specifications wIlhoul nolIcI. Dimensions \lIven In U,S. Incheslollowed by ~ in p.r~the..., ,... I1W Horton 4242 Baldwin Boulevard Corpus Christi. Texas 78405-3399 512-888-5591 800-531-3111 Fax 512-888-6510 Fax 800-531-3108 http://www.honondoors.com ~[R1~[}={]~u~~uQJJ~~[L ~~~~~ AUTOMATIC SLIDING DOORS AUTaMATICS SERIES 2000 ELECTRIC OPERATOR WITH ALUMINUM DOORS A5.0 2/84 Revised 5/97 Note to Spec. Writer: Refer to pages A8.0 - AB. 7 for Specification Details. DIVISION 8 DOORS AND WINDOWS SECTION 8 AUTOMATIC SLIDING DOORS AND OPERATORS PART I GENERAL 1.01 DESCRIPTION This section covers the furnishing and installation of a complete automatic sliding door system. It includes operator. track, doors and activating devices all as required for installation as shown and specified. 1.02 RELATED WORK COVERED BY OTHER APPLICABLE SECTIONS OF THE SPECIFICATION SHALL INCLUDE: A. PREPARATION OF OPENING B. FLOOR PREPARATION C. ELECTRICAL SUPPLY AND CONNECTIONS D. GLASS AND GLAZING 1.03 QUALITY ASSURANCE A. ANSI A 156.1 0 STANDARD: Automatic entrance doors shall be in compliance with applicable requirements of Power Operated Pedestrian Door Standard where applicable to door type. B. UL 325: Powered door operators shall be in compliance with UL 325, Electrical Door, Drapery, Gate, Louver and Window Operators and Systems. C. MANUFACTURERS QUALIFICATIONS: Door units shall be produced by a firm with not less than (5) five years successful experience in the fabrication of automatic doors of the type required for this project. D. INSTALLERS QUALIFICATIONS: Installer must be an authorized representative of the automatic door manufacturer for both the installation and maintenance of the type of units required for the project. 1.04 SUBMITTALS A. PRODUCT DATA: Manufacturers product data and standard details shall be provided for automatic entrance doors, including fabrication, finishing hardware, operators, accessories and other components of the work. Rough-in diagrams. wiring diagrams, parts lists, maintenance instructions. as well as certified test data (where required) shall also be provided. B. TEMPLATES AND DIAGRAMS: Templates. diagrams and other data shall be furnished to fabricators and Installers of related work, as needed for coordination of automatic entrance installation. C. SHOP DRAWINGS: Applicable shop drawings shall be submitted for the fabrication and installation of automatic entrance doors and associated components of the work. Indicate anchors. joint system, expansion provisions, hardware and other components not included in manufacturers standard data. Include glazing details (where required). 1.05 WARRANTY Horton Automatics (Seller) shall warrant to the Buyer that all products they manufacture to be free of any defects in material and workmanship. under normal use and service. for a period of one year from the date product is installed and placed In operation. Generally, the installing dIstributor shall provide a one-year warranty covering the labor, defective parts and transportation charges. ... ...,...,...., --...... -..........- lJ"__.... _......l. I I"'_~ '- I' "'" IiW Hotton 4242 Baldwin Boulevard Corpus Christi, Texas 78405-3399 512-888-5591 800-531-3111 Fax 512-888-6510 Fax 800-531-3108 http://www.hortondoors.com ~[R1~[}={]~lJ'~~u(!JJ[R1~LL ~[?)~CG~ AUTOMATIC SLIDING DOORS AUTOMATIC' SERIES 2000 ELECTRIC OPERATOR WITH ALUMINUM DOORS AS.O 2184 Revised 5/97 Note to Spec. Writer: Refer to pages AS. 0 - A8. 7 for Specification Details. DIVISION 8 DOORS AND WINDOWS SECTION 8 AUTOMATIC SLIDING DOORS AND OPERATORS PART I GENERAL 1.01 DESCRIPTION This section covers the furnishing and installation of a complete automatic sliding door system. It Includes operator, track, doors and activating devices all as required for installation as shown and specified. 1.02 RELATED WORK COVERED BY OTHER APPLICABLE SECTIONS OF THE SPECIFICATION SHALL INCLUDE: A. PREPARATION OF OPENING B. FLOOR PREPARATION C. ELECTRICAL SUPPLY AND CONNECTIONS D. GLASS AND GLAZING 1.03 QUALITY ASSURANCE A. ANSI A156.10 STANDARD: Automatic entrance doors shall be in compliance with applicable requirements of Power Operated Pedestrian Door Standard where applicable to door type. B. UL 325: Powered door operators shall be in compliance with UL 325, Electrical Door, Drapery, Gate, Louver and Window Operators and Systems. C. MANUFACTURERS QUALIFICATIONS: Door units shall be produced by a firm with not less than (5) five years successful experience in the fabrication of automatic doors of the type required for this project. D. INSTALLERS QUALIFICATIONS: Installer must be an authorized representative of the automatic door manufacturer for both the installation and maintenance of the type of units required for the project. 1.04 SUBMITTALS A. PRODUCT DATA: Manufacturers product data and standard details shall be provided for automatic entrance doors, including fabrication, finishing hardware, operators, accessories and other components of the work. Rough-in diagrams, wiring diagrams. parts lists, maintenance instructions, as well as certified test data (where required) shall also be provided. B. TEMPLATES AND DIAGRAMS: Templates, diagrams and other data shall be furnished to fabricators and installers of related work, as needed for coordination of automatic entrance installation. C. SHOP DRAWINGS: Applicable shop drawings shall be submitted for the fabrication and installation of automatic entrance doors and associated components of the work. Indicate anchors, joint system, expansion provisions, hardware and other components not included in manufacturers standard data. Include glazing details (where required). 1.05 WARRANTY Horton Automatics (Seller) shall warrant to the Buyer that all products they manufacture to be free of any defects in material and workmanship, under normal use and service, for a period of one year from the date product is installed and placed In operation. Generally, the Installing distributor shall provide a one-year warranty covering the labor, defective parts and transportation charges. ....,......v __v V_V_ ___I\. '-'_l' l l\.VW "t!U ....,"" ur.MArICI 4242 Baldwin Boulevard Corpus Christi, Texas 78405-3399 512-888-5591 800-531-3111 Fax 512-888-6510 Fax 800-531-3108 http://www.hortondoors.com ~~~~~~~u~~&~~~~~~ ITII lodon AUTOMATIC SLIDING DOORS SERIES 2000 ELECTRIC OPERATOR WITH ALUMINUM DOORS A5.1 2/84 Revised 5/97 () tART 1- CONT. .06 COMPLIANCE A completed American Association of Door Manufacturer (AAADM) Inspection form shall be submitted as proof of compliance with ANSI A 156.10 Standard for power operated pedestrian doors. Door(s) shall be inspected and form shall be signed by an AAADM certified inspector prior to placing door(s) in operation. I ART II - PRODUCTS ..01 MANUFACTURER Automatic sliding door(s) shall be of type(s) and size(s) as indicated on plans, manufactured by Horton Automatics, a division of Overhead Door Corporation. !.02 EQUIPMENT A. DOOR UNIT: The door unit shall Include operator, header and track, sliding door(s), threshold (most units), sidelite(s) and jambs. All structural aluminum header sections shall be 6063T-5 anodized aluminum no less than 3/16" (5 mm) thick and shall be capable of self support up to a length of 16 feet (4877 mm) on standard door size and glazing. The header shall be 4" (102 mm) deep by 6" (152 mm) high, the nylon covered track shall be replaceable without having to remove the operator and shall be 1/4" (6 mm) wide. Rollers shall be ledloy steel '.') high quality ball bearing wheels 1-1/4" (32 mm) in diameter. Concealed guides shall stabilize bottom of sliding '-. door panel. Anti-derailing means shall be a continuous extrusion full length of door travel. All unit types shall be perimeter mounted unless specifically designed to be surfaced mounted. Telescoping (Space Saver) Door Units: Access to the operator and synchronizing mechanism shall be from both sides of the header. The sliding panels shall be equipped with a synchronizing cable and speed regulating mechanism that will cause the leading sliding panel to open twice as fast as the adjacent sliding panel. When the panels are in the open position they shall provide a net opening of approximately 70% of the overall package width. The sliding system shall be constructed of two separate tracks for the two-speed sliding door systems to travel. OPTIONAL DOOR UNIT EQUIPMENT: . Transom of size indicated mounted on header . Additional and/or extra wide sidelltes of size indicated . Recessed sidelfte and track and non-threshold application All exposed aluminum surfaces shall be: a. Standard finish: 204-R1 clear anodized b. Stock finish: 313-R1 dark bronze anodized c. Special anodized finish as indicated d. Special paint finish as Indicated e. Clad with stainless steel or muntz metal (brass color) Sliding Door Panels and Sldelltes: All structural aluminum sections shall be 6063T -5 alloy with safety radius comers on all vertical rails. An adjustable astragal with double mohair weather-strip shall be provided on all strike J rails. Joining vertical panel rails and horizontal rails shall have mohair weatherstripping. Door panel construction . shall have mechanical Joints. Door units provided with the emergency breakout feature shall require no more than 50 Ibf. (222 N) of force applied at the lock stile for the breakout panel to open. Swing-slide panels and swing-out sidelites shall include a torsion spring to re-close the door if pushed open in the direction of egress. Pushbars shall be sent loose to be field mounted if no mid rail is specified on breakout units. .---- ---... --.......-- ITII Honon 4242 Baldwin Boulevard Corpus Christi, Texas 78405-3399 512-888-5591 800-531-31 J 1 Fax 512-888-6510 Fax 800-531-3108 http://www.hortondoors.com AUTOMATIC SLIDING DOORS ~~CC;[g]OlJ[g~lJM~~G:, @~~~@ AITOMATICI SERIES 2000 ELECTRIC OPERATOR WITH ALUMINUM DOORS A5.2 ~84 Revised 5/97 PART II, SPEC. 2.02 - CONT, Sliding Door Panels and Sidelite Options: . Horizontal muntin (midrail) . Medium and wide stile horizontal and vertical rails . Prep for glazing 5/16" (16 mm) to 1" (25 mm). It shall be noted that 1/2" (13 mm) glass and above is not recommended on sliding panels for the following reasons: maximum total weight of breakout panel shall not exceed 156 Ibs (70.7 kg) as per UL requirement and maximum total weight of non-breakout panel shall not exceed 200 Ibs (90.7 kg). Sliding Door Panel Hardware: Sliding panel (X or SX) shalf have Adams Rite Maximum Security Lock MS1B53A505 31/32" (25 mm) with 1 5/32" (29 mm) standard size cylinder. Type SX with UL listing has 6410 Thumb Turn inside and standard cylinders outside. Biparting SX doors shalf be provided with two point deadlock hook bolt for adjacent panel or jamb and lock bolt into the top carrier frame. Hardware Options: . Reverse lock bolt shalf drop into threshold . Panic Hardware - Adams Rite 8600 available on Series 2310 only (described below) Door unit shall be one of the following series numbers: a. Series 2010 (O-X): The non-breakout sliding panel (X) shall be installed to the interior of fixed sidellte (0) and shall slide along sidelite. b. Series 2010 (P-X) Surface Mounted: The unit shall be surface mounted to the interior of the wall. The non- breakout sliding panel (X) shall slide along the wall (pocket area - P). . c. Series 2010T (O-X-X) Telescoping (Space Saver): The non-breakout sliding panels (X) shall be installed to inside of fixed sidelite (0) and shall slide along sidelite. d. Series 2110 (O-SX) The swing-slide panel (SX) shall be Installed to the exterior of the fixed sidelite (0) and shall slide along sidelite. f e. Series 2110 (P-SX) Surface Mounted: The unit shall be surface mounted to the exterior of the wall. The swing- slide panel (SX) shall slide along the wall (pocket area - Pl. f. Series 211 OT (O-X.SX) Telescoping (Space Saver): The swing-slide panel (SX) shall be installed to the exterior of the non-breakout sliding panel (X) which shall be installed to the exterior of the fixed sldelite (0). Both sliding panels shall slide along sidelite. g. Series 2310 (SO-SX) The swing-slide panel (SX) shall be installed to the interior of the swing out sidelite (SO) and shall slide along sidelite. h. Series 2310T (SO-SX-SX) Telescoping (Space Saver): The swing-slide panel (SX) with strike rail shall be installed to the Interior of the non-strike swing-slide panel (SX) which shall be installed to the interior of the swing outsidelite (SO). Both sliding panels shall slide along sldelite. i. Series 2410 (O/SO-SX) The swing-slide panel (SX) shall be installed between the interior fixed sidelite (0) and the ~xterior swing pocket panel (SO) and shall slide along sidellte. No locks shall be applied to swing pocket panel. All swing-slide panels (SX) shall swing out 90 degrees from any position of slide movement and shall be UL listed as an exit way. All swing out sidelites (SO) shall have a switch installed In the sidelite to stop automatic operation when the sidelite is open. All door units described above in single slide configurations shall also be available in bipart configurations. B. OPERATOR: Shall be an electromechanical, utilizing a 1/8 Hp, DC permanent magnet motor and unique linear drive to transmit power to the door. It shall be header mounted and concealed with a securely attached, removable cover. ITII Rorton 4242 Baldwin Boulevard Corpus Christi. Texas 78405-3399 512-888-5.591 800-531-3111 Fax 512-888-6510 Fax 800-.531-3108 http://www.hortondoors.com AUTOMATIC SLIDING DOORS ~[R1@IHJOlJ[g~lfQJJ[Rl~[L ~~!g~~; . ;. I ~ IIT.MATIC. SERIES 2000 ELECTRIC OPERATOR WITH ALUMINUM DOORS 'A5.3 2184~ Revised 5197 \~;1 'ART II, SPEC. 2.02 - CONT. The Open Check, Open Cut-Off, Close Check, and Close Cut-Off microswitches shall be fully and Independently adjustable and shall instruct the C2150 microprocessor master control on the sliding panel's position. Speed values for Open Speed, Close Speed, Open Check, Close Check, and Open Cushion parameters shall be programmable utilizing the operators master control. Time values for FuU-open Time Delay and Partial-Open Time Delay shall also be programmable through the microprocessor control. Control shall Include a digital display for diagnostic evaluation. Closing speed shall not exceed 12" (305 mm) per second. Opening speed shall be capable of opening a biparting door at a rate of 60" (1524 mm) per second If total door weight Is less than 300 Ibs. (181 kg.). Doors heavier than 300 Ibs. (total) shall be operated at a slower rate. The operator shall reverse when maximum force of 28 Ibs. (13 kg.) is exerted to prevent the door from closing. The reverser shall be field adjustable to meet job conditions. A power ON/OFF switch shall be located on the Inside of the header. The OFF position shall serve as a programming mode. In the event of an electrical power failure or if the unit has been manually switched OFF the operator shall revert to free manual operation of the door. OPERA TOR OPTIONS: . Autolock C2176-5 Fail Secure (if power fails the lock shall engage) . Autolock C2196-5 Fail Safe (if power fails the lock shall disengage) . Power Fail Open (if power fails the door shall slide open) . Power Fail Close (If power fails the door shall slide closed) . ")" ". !.03 CONTROL SWITCH A. MOTION SENSORS: A motion sensor shall be mounted to the header on each side of the door for detection of traffic in each direction. Detection pattern must be as wide as door opening and extend out 48" (1372 mm) minimum. Detection shall be within 5" (127 mm) of door. B. PHOTOELECTRIC BEAMS: Two C1185 photoelectric beams shall be mounted in the vertical rails of the sldellte or in the jambs at heights of 24" (610 mm) and 48" (1219 mm). Each shall parallel door opening and, when interrupted, serve as a hold-open device when door is in open position and shall recycle the door when it is closing. Beams shall not activate door when unit is fully closed. Each switch shall be 24 VAC, class II circuit. Optional system shall include: Two motion sensors, a presence sensing device mounted to the door header that shaJJ scan through the threshold opening and a photoelectric beam mounted in the vertical rail that shall parallel the door opening. The C2150 master control shall have four modes of operation: day 1-way, day 2-way, night 2-way, and night 1-way. In day 1-way mode, all sensors shall remain enabled throughout the hOld-open and closing modes for maximum safety, per ANSI standard A 156.10, section 5.2.3. Optional Selector Switches: . C3725 Double Key Switch - includes 2-Way Automatic, Hold Open, Off, 1-Way Exit, Full Open and Partial Open positions. 1-314" x 4-112" (44 x 114 mm). . C3726 Double Rotary Switch - includes 2-Way Automatic, Hold Open, Off, 1-Way Exit, Full Open and Partial Open positions. 1-3/4" x 4-1/2" (44 x 114 mm). . C3725-1 Single Key Switch - includes 2-Way Automatic, Hold Open, Off and 1-Way Exit positions. ) 1-3/4" x 4-112" (44 x 114 mm). '. . C3726 -1 Single Rotary Switch - Includes 2-Way Automatic, Hold Open, Off, 1-Way Exit, Full Open and Partial Open positions. 1-314- x 4-112" (44 x 114 mm). . C131-4 Latch Relay - signal to open, signal to close - - . - -- rrw Honon 4242 Baldwin Boulevard Corpus Christi. Texas 78405-3399 512-888-5591 800-531-3111 Fax 512-888-6510 Fax 800-531-3108 http://www.hortondoors.com ~[R1(g[H]OIJ[g~IfM[Rl~G:. ~~[g~~ AUTOMATIC SLIDING DOORS AUTOMATIC' SERIES 2000 ELECTRIC OPERATOR WITH ALUMINUM DOORS AS.4 2/84 Revised 5/97 PART II - CONT. 2.04 REQUIREMENTS FOR WORK SPECIFIED IN OTHER SECTIONS A. ELECTRICAL: The general contractor or electrical contractor shall furnish and install all wiring to operator. 120 VAC, 60 cycle, 1 phase, 15 amp seNice shall be provided to each operator on a separate circuit breaker routed into header. B. GLASS AND GLAZING: Shall be provided under glass and glazing section of specifications. Glazing shall be in strict accordance with manufacturers instructIons (ANSI Standard Z97.1). Exception: ElegantrM all glass doors are provided as part of the automatic door package. PART III - EXECUTION 3.01 INSPECTION Installer must examine the areas and conditions under which automatic doors are to be installed and notify the Contractor in writing of conditions detrimental to the proper and timely completion of work. Do not proceed with the work until all unsatisfactory conditions have been corrected in a manner acceptable to the installer and in accordance with approved shop drawings. 3.02 INSTALLATION Complete door package and operator system including drive mechanism, controls and control switches shall be installed in accordance with manufacturers instructions, specifications and recommendations. Installation shall be done by an authorized Horton Automatics Distributorrrechnician. 3.03 ADJUSTMENT AND CLEANING Installer shall clean surfaces promptly after installation and shall lubricate operating eq'Jipment for optimum condition and safety. Contractor shall be advised of protective treatment and other precautions required through the remainder of the construction period, to ensure that doors will be without damage or deterioration (other than normal weathering) at the time of acceptance. Installer shall adjust operator and controls for optimum condition and safety. END OF SECTION