Tall Trees Water .. Water Systems Operation Report Microbiological Sample Results Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 Name of Public Water System Program Code Federal Reporting MonthNear Tall Trees Water 100 1302809 April 2005 Location: TOWN OF WAPPINGER Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? CHLORINATION Amount of Gaseous Liquid Treated Chlorine Hypo- Free Water Weight of Used chlorite Chlorine Date 1,000 Gals. Cylinder Lbs. per Used Residual pH Per Day Lbs. 24 Hrs. Qts. mg/I 1 16.70 20 0.8 2 20.30 28 0.9 3 23.70 30 1.0 4 18.00 22 0.9 5 21.00 24 0.9 6 22.10 32 0.9 7 18.70 20 0.9 8 20.00 24 0.7 9 21.90 28 1.0 10 24.20 36 0.9 11 20.90 28 1.1 12 19.40 24 0.9 13 20.00 30 0.9 14 17.80 22 0.7 15 21.50 28 1.1 16 21.30 32 1.0 17 26.20 34 1.0 18 24.50 34 0.8 19 28.00 36 0.9 20 22.40 26 0.8 21 21.60 28 1.0 22 19.10 28 1.0 23 24.60 34 1.0 24 22.30 28 0.8 25 21.70 28 0.8 26 20.90 28 0.9 27 20.70 26 1.0 28 19.20 24 0.8 29 21.30 28 0.8 30 22.40 32 0.8 31 Total 642 842 27 Avg. 21.41 28.1 0.9 County: DUTCHESS I Ground I ~~ Population served: 251 Number of required routine samplE 1 Number of actual routine samples 1 Does a M&AR violation exist? NO If yes, check reason(s) below: _ Actual number of samples fewer than required. _ Failure to analyze for E.coli if there was a positive result for total coliforms from routine. repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes. check reason(s) below: _ Two or more positive total coliform samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total coliform samples for systems collecting 40 or more samples (routine, repeat or hiturb) per month. _ When a positive total Coliform sample is positive for E.coli and a repeat Total Coliform sample is positive, OR, when a positive Total Coliform sample is negative for E.coli, but the repeat Total Coliform sample is positive and aiso is positive for E.coli. . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Date: .5/'-1/6 S (f. ~~..~ ~~- Reported by: CAMO Pollution Control, Inc. Title: Operator Grade Level: IIA Cert. No. 12947 Distribution System Analytical Results Sampling Date of Sample Total Coliform E.coli Free CI- Raw Location Sample Type Positive Positive Residual Turbidity (1,2,3)' mg/L NTU POE 4/13/05 1 No No 0.8 - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - *1 = Routine sample 2 = Repeat sample 3 = Hiturb sample COMMENTS and/or REMARKS . u z - ... en ~ a: o s: ~ OJ ~ <C -J -J <C J- Z W :: z o a: - > z w t: o >- i:('f');:-.:t Q)NQ')C'\I ZCOC(CC e-r-;-- ~;= .8~~~ ~Nl.C')g ~ ~~ D- o 00 ;;-:5 M-roW ~ u.. x o CJ o a.: ~ C:=> c::::> "" <:J 00 r{ " 0 ffl M /!!>- - ~D "" a: Cl go u; aZ ~ co F-1 r:- E.: <.r: "'," ,,'J ',.-::.-':J 'I\: UJ Z o :x: a: ll. ~ ~ ~ ~ ~ ~~ g ::".",-q [-7,"} '., ) L:j .-"~ f.'::':;'J a: w I- < 3: u. o z o F= < z :e < )( W ..J < g C) o ..J o a: w l- t) < r:c w if ::;) ~ ~ ~ C .... ~ ~ III ~ !~ -' w a: ~~~(- ~o.. ~ , ~ 2 w ~ o I? >- 0 ~ ~ ll. c ;:) ::i CI) gj UJ 0 I- ... ~ :r a: g ll. a:: r- >- t: -l < ;::> 0' >- c<: <( .... Z < CI) >- ~ 0::: 0 ~ C@ Q <~ ~~ ~~ CI)~ ~~ J O~ ...:l ~ ~ ~ ....' CIl I:! >- ~ ,:Q Q ~~ ~ t:t: ~~ ~ LIJO :;a i=.... ~tl ::cUJ ....81 u:~ I-PI: <2; u a ?: