Loading...
Tall Trees Water Water Systems Operation Report Microbiological Sample Results Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 Name of Public Water System Program Code Federal Reporting MonthlYear Tall Trees Water 100 1302809 December 2004 Location: TOWN OF WAPPINGER Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? CHLORINATION Amount of Gaseous L1auld Treated Chlorine Hypo- Frea Water Weight of Used chlorite Chlorine Date 1.000 Gals. Cylinder Lbs.per Used Residual pH Per Day Lbs. 24 Hrs. Qts. mg/1 1 20.50 28 0.9 2 20.60 28 1.0 3 19.70 32 1.0 4 16.80 28 1.0 5 20.50 28 1.2 6 20.80 28 1.0 7 18.60 24 1.1 8 20.00 22 1.0 9 19.10 24 0.9 10 18.10 28 1.0 11 20.60 32 0.9 12 22.60 26 1.2 13 17.30 14 1.1 14 21.00 24 1.0 15 20.60 24 1.0 16 17.10 26 1.0 17 19.20 28 1.1 18 20.40 34 1.0 19 21.90 32 1.2 20 21.10 32 1.3 21 19.70 28 1.0 22 19.10 24 0.9 23 26.20 40 1.1 24 19.70 32 1.0 25 20.50 26 1.0 26 20.50 26 1.0 27 22.40 30 1.3 28 20.50 28 1.2 29 20.00 28 0.8 30 22.10 28 1.0 31 25.00 36 0.8 Total 607 868 32 Avg. 20.39 28.0 1.0 County: DUTCHESS I Ground I ~~ Population served: 251 Number of required routine samplE 1 Number of actual routine samples 1 Does a M&AR violation exist? NO If yes, check reason(s) below: _ Actual number of samples fewer than required. _ Failure to analyze for E.colllf there was a positive result for total coliforms from routine. repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason(s) below: _ Two or more positive total coliform samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total coliform samples for systems collecting 40 or more samples (routine, repeat or hiturb) per month. _ When a positive total Coliform sample is positive for E.coll and a repeat Total Coliform sample Is positive, OR. when a positive Total Coliform semple is negative for E.coll, but the repeat Total Coliform sample Is positive and also is positive for E.coIi. . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Reported by: CAMO Pollution Control, Inc. Title: Operator Date: ;/1 ( / () 5 . ~.'----- Grade Level: itA Cert.No. 12947 Distribution System Analytical Results Sampling Date of Sample Total Coliform E.coli Free CI- Raw Location Sample Type Positive Positive Residual Turbidity (1,2,3)* mg/L NTU P.O.E 12/10/04 1 No No 0.5 - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - *1 = Routine sample 2 = Repeat sample 3 = Hiturb sample COMMENTS and/or REMARKS ENVIRONMENTAL LABWORKS, INC. BOTTLE NUMBER t... { ()r;) t J ( COLLECTED BYJ J.. J EXACT COLLECTION POINT ol,t.;;e/Z- NAMe ANOiOR LOCATIONS OF WATER SOURCE: .--.- P.O. Box 733, Marlboro, N_York 12542 (845) 236-7823 Fax (845) 236-3911 ELAP 10# 10824 PRIVATE SUPPLY Q REPORT TO BE MAJU:D TO BACTERIOLOGICAL EXAMINA liON OF WATER "J-. -... - - -.. -.j, " ?f?llJ _..,I....,-q. RESULTS OF EXAMINATION BACTERIA I lolL AT :J5oC TOTAl CClLFOAMS 11Clll101t. ABSENT METHOD OF EXAMINATION PIA C MPN C MF C CoIIIert OTHER TESTS REMARKS INTERPRETATION OF RESULTS TIiESE RESULTS INDICAn TIiATTIiE WATER WAS IN RESPECl' TO THE ABOVE TEST, WHEN REPORTED BY OF A SATISFACTORY SANITARY QUALITY WAS ANALVZED.. DATE z.. c=, 0