Loading...
Fleetwood Water Facility Water Systems Operation Report Microbiological Sample Results Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 Name of Public Water System Program Code Federal Reporting MonthlYear Fleetwood Water Facility 100 1302779 December 2004 Location: TOWN OF WAPPINGER Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? CHLORINATION Amount of Gaseous Liquid Treated Chlorine Hypo- Free Water Weight of Used chlorite Chlorine Date 1,000 Gals. Cylinder Lbs. per Used Residual pH Per Day Lbs. 24 Hrs. ats. mgll 1 34.5 0.4 2 34.5 0.3 3 34.5 0.3 4 34.5 0.4 5 34.5 0.3 6 34.5 0.3 7 34.5 0.3 8 34.5 0.3 9 34.5 0.1 10 34.5 0.3 11 34.5 0.3 12 34.5 0.2 13 34.5 0.1 14 34.5 0.2 15 34.5 0.2 16 34.5 0.3 17 34.5 0.3 18 34.5 0.3 19 34.5 0.3 20 34.5 0.3 21 34.5 0.3 22 34.5 0.3 23 34.5 0.3 24 34.5 0.3 25 34.5 0.3 26 34.5 0.3 27 34.5 0.3 28 34.5 0.3 29 34.5 0.3 30 34.5 0.3 31 34.50 0.4 Total 1,070 9 Avg. 34.50 0.3 County: DUTCHESS I Ground I~~ Population served: 564 Number of required routine samplE 1 Number of actual routine samples 1 Does a M&AR violation exist? NO If yes, check reason(s) below: I 32.10 , _Actua~ 32.10 _ Failure to analyze for E.coli if there was a positive result for total coliforms from routine, repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason( s) below: _ Two or more positive total coliform samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total coliform samples for systems collecting 40 or more samples (routine, repeat or hiturb) per month. _ When a positive total Coliform sample is positive for E.coli and a repeat T9tal Coliform sample is positive, OR, when a positive Total Coliform sample is negative for E.coli, but the repeat Total Coliform sample is positive and also is positive for E.coli. . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Date: I/f/og ~.~ ~ ~~ Reported by: CAMO Pollution Control, Inc. Title: Operator Grade Level: IIA 12947 Cert. No. Distribution System Analytical Results Sampling Date of Sample Total Coliform E.coli Free CI- Raw Location Sample Type Positive Positive Residual Turbidity (1,2,3)* mg/L NTU Meter Pit 12/13/04 1 No No 0.1 - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - _Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - *1 = Routine sample 2 = Repeat sample 3 = Hiturb sample COMMENTS and/or REMARKS ENVIRONMENTAL LABWORKS, INC. P.O. Box 733, Marlboro. New-YOIlt 12542 (845) 236-7823 Fax (845) 236-3911 ELAP 10# 10824 BACTERIOLOGICAL EXAMINA liON OF WATER F;:, ~-:-f ~~I::J" ':; 71 ')7 IT';' " --"oW '.... ~.J 1 ~..:I u.., tJ nr:r> 1 ~ ".. b'~'" . .,) l.uG4 RESULTS OF EXAMINATION BACTERIA I lolL AT 35-C TOTAl. ca.JFORMS /10CMl. ABSENT METHOD OF EXAMINATION PIA C MPN C MF C CoIDert}P OTHER TESTS REMARKS . INTERPRETATION OF RESULTS TIiESE RESULTS INDICATE TIiAT THE WATER wn~ OF A SATISFACTORY SANITARY QUALITY IN' RESPECT TO TIm ABOVE TEST, WHEN mE SAMPLE WAS ANAL VZEO. . ~~U1f~ DATE 12-14-04 REPOR1ED BY ~