Loading...
Wappingers Park Water Name of Public Water System Program Code Federal Reporting MonthNear Wappigners Park Water 100 1302782 September 2004 i# ~ Water Systems Operation Repc\...f Microbiological Sample Results Location: TOWN OF WAPPINGER Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? CHLORINATION Amount of Gaseous Liquid Treated Chlorine Hypo- Free Water Weight of Used chlorite Chlorine Date 1,000 Gals. Cylinder Lbs. per Used Residual pH Per Day Lbs. 24 Hrs. Qts. mg/l 1 17.90 46 1.5 2 20.10 52 1.2 3 20.30 52 0.9 4 19.20 48 0.9 5 17.20 40 0.5 6 20.10 48 0.6 7 19.80 50 0.9 8 18.70 70 1.4 9 19.20 58 1.5 10 17.70 52 0.9 11 14.70 44 0.3 12 24.40 68 1.3 13 23.40 62 0.6 14 16.70 44 0.4 15 17.70 46 0.3 16 20.90 58 1.6 17 17.00 44 1.2 18 19.50 48 1.1 19 19.50 48 1.1 20 17.30 40 0.7 21 20.30 48 1.1 22 19.70 56 to 23 15.80 40 1.1 24 18.30 44 1.3 25 16.40 40 0.7 26 22.30 30 1.2 27 16.70 40 1.9 28 16.20 40 0.9 29 17.20 42 2.0 30 17.30 48 1.6 31 Total 41,756 1,446 32 Avg. 18.72 48.2 1.1 Reported by: CAMO Pollution Control, Inc. Submitted By: ~AMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 County: DUTCHESS I Ground I~~ Population served: 400 Number of required routine samplE 1 Number of actual routine samples 1 Does a M&AR violation exist? NO If yes, check reason(s) below: _ Actual number of samples fewer than required. _ Failure to analyze for E.coli if there was a positive result for total colifonns from routine, repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason(s) below: _ Two or more positive total colifonn samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total colifonn samples for systems collecting 40 or more samples (routine, repeat or hiturb) per month. _ When a positive total Colifonn sample is positive for E.coli and a repeat Total Colifonn sample is positive, OR, when a positive Total Collfonn sample is negative for E.coli, but the repeat Total Colifonn sample is positive and also is positive for E.coli. . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Title: Operator Date; /D /% /0 t..( I ' ~0 !,.~.... _ _ Grade Level: IIA Cert. No. 12947 ~ rl ~I ~ E \wi C) 0- C'..I 0- L"') ~ T"-i 0 U) oW "? ~>- ....... ~D .. ~O ~ 9 f::~ C/) OZ < ~:-~;J ;: f- . 0.. Z (.) ~;:J) < ~ ,.., ell Z Lti W >- t:: Z ~. - f",) 0 O~ < ... l1.:j :I: C@ Cl en ~ a: a.. w ~ <~ .... ~ a: ~ ...... I!:! ~;2 a: LU l!s \) ~~ ... w 0 <( If a ~ ~~ == ~ ~ 0 ?; ~ N U. a.. 0( o~ .:1; 0.. ::I m 0 0 ::> ~ U) III <( i!: Z 0 W ~ 0 I- >- 0 ~ .... ..J aM;;~ a: j:: 2 z~'?~ <( a: w ..J .."CO~ 0.. a: <( ~~~~ Z Nlt)_ !i ~G'::l!ia.. t- .~;z5 <( ~ C"')-caW Z "" u. >< ~ .... >- W ~ W /Xl :: 0 ..I ~ 0 0.: <( ~~ ~ Z (,) 0 G ~~ 0 ~ a: ..J t1.Io Q i:~ - ~O > a: Z w ::tie ... ~.~ W (,) w <( &! <~ m ~ u Q .. is a: = I!! \I) ; ~ ~ ;:) -....(~ g ~ .... ~ ffi J~l.Ug t1.I g] 7> u i: CD CD wOa: ~OS oJ g ~ ~ 0 ~ ~-~ .... w U ::I g~g ~ 0( w Z