Loading...
Wappingers Park Water CHLORINATION Amount of Gaseous Liquid Treated Chlorine I Hypo- Free Water Weight of Used I chlorite Chlorine , pH Date 1,000 Gals. Cylinder Lbs. per I Used Residual Per Day Lbs. 24 Hrs. Ots. mgll 1 20.80 40 1.0 7.2 2 14.20 24 0.5 7.2 3 24.10 44 1.0 7.2 4 20.10 36 0.6 7.2 5, 18.40 36 0.3 7.2 61 18.90 24 0.4 7.2 7 20.80 40 0.6 7.2 8 27.50 50 0.6 7.2 9 24.40 48 0.5 7.2 10 16.80 32 0.3 7.2 11 19.30 36 0.5 7.2 12 18.90 36 0.8 7.2 13 19.10 32 1.0 7.2 14 11.90 28 0.5 7.2 15 24.40 48 1.0 7.2 16 23.90 I 48 1.0 7.2 17 21.20 I 44 0.3 7.2 18 I 17.50 32 0.5 7.2 19 18.20 36 0.7 7.2 20 i 15.00 36 1.0 7.2 I 21 i 12.00 28 0.7 7.2 I 22 24.10 46 1.0 7.2 23 19.50 40 1.2 7.2 24 16.00 32 0.8 7.2 25 16.20 32 0.8 7.2 26 13.40 28 0.6 7.2 I 27 16.50 32 0.4 7.2 K81 18.30 i 34 0.2 7.2 29 12.40 24 1.0 7.2 30 22.70 44 1.0 7.2 I 31 I Total 567 1,090 21 216 i Avg. 18.27 36.3 0.7 7.2 .- Water Systems Operation Report Microbiological Sample Results Name of Public Water System Program Code Wappingers Park Water 100 Location: TOWN OF WAPPINGER Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? Reported by: CAMO Pollution Control, Inc. Title: Operator Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 Federal Reporting MonthNear I ! 1302782 September 2001 County: DUTCHESS Ground No No No Population served: 400 Number of required routine sampl 1 Number of actual routine samples 1 Does a M&AR violation exist? NO If yes, check reason(s) below: _ Actual number of samples fewer than required. _ Failure to analyze for E.coli if there was a positive result for total coliforms from routine. repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason(s) below: _ Two or more positive total coliform samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total coliform samples for systems collecting 40 or more s.amPlesRutine, repeat or hiturb) per month. C~\"E.\J _ Wha'€!tiV; total xOlj~~'amPle is positive for E.coli and a rep~rT~al Colftorm sample is positive, OR, when a positive'Total Coliform sa~\,negative for E.coli, but the repeat T~~tGb'Jiip'e is positive and also is positive for E~'ttJ '\I ~. . . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Date: /0/0/0, I ~ ^-~~ \ Grade Level: IIA Cert. No. 12947 ENVIRONMENTAL LABWORKS, INC. PO Box 733, Mar1boro, New Yorl<: 12542 (845) 236-7823 Fax (845) 236-3911 ELAP 10# 10824 -j f') 1 ::. ZnOl' BOTTLE NUUBER BACTERIOLOGICAL EXAMINATION OF WATER DATE AND TIM.E RECEIVED '1 II J/r; I d-P n. SAUPlE COllECTED FROt.I PUBUC SUPPLY CHLORINATED NO 0 YES 0 ppmO - S- BACTERIA /Ml AT 35-C TOT At COUFORI.CS /lOO1olL ABSENT OTHER TESTS REMARKS INTERPRETATION OF RESULTS t.IETHOO OF EXAMINATION PIA 0 MPN 0 MF 0 Colilert IX THESE RESULTS INDICATE THAT THE WATER IN RESPECT TO THE ABOVE TEST, WAS OF A SATISFACTORY SANITARY QUALITY LE WAS ANALYZED. REPORTED BY DATE