Loading...
Fleetwood Water Facility Water Systems Operation Report Microbiological Sample Results Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 r Name of Public Water System Program Code Federal Reporting MonthNear \ 1 I Fleetwood Water Facility 100 1302779 September 2001 Location: TOWN OF WAPPINGER County: DUTCHESS Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? Ground No ,No No r \ Amount of CHLORINATION I 1 Gaseous Liquid Treated Chlorine Hypo- Free Water Weight of Used chlorite Chlorine Date 1,000 Gals. Cylinder Lbs. per Used Residual pH Per Day Lbs. 24 H rs. ats. mg/l 1 46.50 0.6 2 27.70 0.5 3 43.50 0.5 4 36.70 0.3 51 45.70 0.2 6 34.50 I 0.2 , 7 40.50 0.3 8 57.00 , 0.4 91 39.70 0.2 10T 39.00 0.2 11 \ 30.70 0.1 12 39.70 I 0.1 13 29.20 0.2 14 31.50 0.1 15 48.70 0.2 16 33.00 0.2 17 33.00 0.2 18 34.50 0.2 I 191 34.50 0.2 \ 20 31.50 0.2 21 33.00 0.2 22 49.50 [ 0.2 i 23 33.20 0.2 ~24 36.70 0.1 i 25 i 35.20 i , 0.2 261 29.20 I 0.2 I 27 36.00 1 I 0.2 281 40.50 ! 0.2 29T 28.50 ! I 0.1 ~1 47.20, i 0.2 , 311 i I I iTotal 1,126 \ 0 7 Avg. i 37.541 r- 0.0 0.2 Population served: 564 Number of required routine sampl 1 Number of actual routine samples 1 Does a M&AR violation exist? NO If yes, check reason(s) below: _ Actual number of samples fewer than required. _ Failure to analyze for Ecoli if there was a positive result for total coliforms from routine, repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason(s) below: _ Two or more positive total coliform samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total coliform samples for systems collecting 40 or more samples (routine, repeat or hiturb) per month. ~r:f'C\VEO .. _ When a posi1V\ liii~IW sample IS poSitive for Ecoli and a repeat Total Coliforgt ~rT\I3\i\~~positive, OR, when a positive Total~Irm b~p~ Wy,~gative for Ecoli, but the repeat Total Coliform sample is pOSitive and also is positive for E.coli. TOWN CLERK . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Reported by: CAMO Pollution Control, Inc. Date: 10/ q /0 ( &~~ Grade Level: IIA Title: Operator Cert. No. 12947 Distribution System Analytical Results Sampling Date of Sample Total Coliform E.coli Free CI- Raw Location Sample Type Positive Positive Residual Turbidity (1,2,3)* mg/L NTU Fleetwood STP 09/19/01 1 No No 0.2 Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No *1 = Routine sample 2 = Repeat sample 3 = Hiturb sample COMMENTS andlor REMARKS ENVIRONMENTAL LABWORKS, INC. P.O. Box 733, Marlboro, New York 12542 (845) 236-7823 Fax (845) 236-3911 ELAP 10# 10824 ~ :-,'" i" ~ "', .~ 't ::.......c.~-...... 'oiI:::'~ ~; .j 1 2001 BOTILE NUJ,lBER BACTERIOLOGICAL EXAMINATION OF WATER pp~ PRIVATE SUPPLY 0 REPORT TO BE MAILED TO n F f f7 e+UX::c~J:> THESE RESULTS INDICATE THAT THE WATER WAS OF A SATISFACTORY SANITARY QUALITY IN RESPECT TO THE ABOVE TEST, WHEN THE SAMPLE WAS COLLECTED. CO..\uo..(T c..*cz) DATE 9-20-01 REPORTED BY