Loading...
Atlas Water Facility i Water Systems Operation Report Microbiological Sample Results Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 Program Code Federal Reporting MonthNear I Name of Public Water System I' Atlas Water Facility Location: 100 TOWN OF WAPPINGER Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? I Amount of I CHLORINATION I Gaseous Liquid I Treated ! Chlorine Hypo- Free , : Water Weight of I Used chlorite Chlorine Date11'000 Gals. Cylinder Lbs.per Used Residual pH Per Day Lbs. 24 Hrs. Qts. mgll 1 219.60 148 0.4 7.4 2 211.00 124 0.4 7.4 3 240.10 136 0.4 7.4 4 271.40 148 0.4 7.4 5 248.40 140 0.4 7.4 6 205.90 116 0.6 7.4 7 239.30 132 0.4 7.4 8 224.40 124 0.4 7.4 I 9 171.90 96 0.4 7.4 10 245.40 152 0.4 7.4 11 273.90 150 0.4 7.4 12 226.30 128 0.4 7.4 13 209.30 124 0.4 7.4 14 242.40 I 120 0.4 7.4 ~15 226.60 124 0.4 7.4 16 172.50 100 0.4 7.4 , 17 236.60 144 0.4 7.4 18 235.00 128 0.4 7.4 19 283.10 I 164 0.4 7.4 I 20 225.80 132 0.4 7.4 I 21 177.90 104 0.5 7.4 , 22 211.70 120 0.4 7.4' 23 174.00 132 0.4 7.4 I 24 236.10 132 0.4 7.4 ! 25! 278.70 156 0.4 7.4 i 26 227.30 , 132' 0.4 7.4 I ! I 27 244.20 140 0.4 7.4 28 209.40 i 116 0.4 7.4 29 I 30 31 i I ! I , ! Total I 6,368 I Avg. 1 227.44 Reported by: Title: I Date: S~/o I 81~ 3,6621 130.81 12, 0.41 CAMO Pollution Control, Inc. Operator 1302789 February 2001 County: DUTCHESS Ground ! No No I No I Population served: 1,800 Number of required routine sampl 2 Number of actual routine samples 2 Does a M&AR violation exist? NO If yes, check reason(s) below: _ Actual number of samples fewer than required. _ Failure to analyze for E.coli if there was a positive result for total coliforms from routine, repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason(s) below: _ Two or more positive total coliform samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total coliform samples for systems collecting 40 or more samples (routine, repeat or hiturb) per month. _ When a positive total Coliform sample is positive for E.coli and a repeat Total Coliform sample is positive, OR, when a positive Total Coliform sample is negative for E.coli, but the repeat Total Coliform sample is positive and also is positive for E.coli. . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Grade Level: IIA Cert. No. 12947 Distribution System Analytical Results Sampling Date of Sample Total Coliform E.coli Free CI- Raw Location Sample Type Positive Positive Residual Turbidity (1,2,3)* mg/L NTU Wildwood Laundry 02/20/01 1 No No 0.3 . POE 02/20/01 Yes No Yes No 0.4 Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No *1 = Routine sample 2 = Repeat sample 3 = Hiturb sample COMMENTS and/or REMARKS ENVIRONMENTAL LABWORKS, INC. P.O. Box 733, Martboro, New York 12542 (845) 236-7823 Fax (845) 236-3911 ELAP 10# 10824 R E eEl V E 0 MAR - 1 ZOOt BOTTLE NUMBER BACTERIOLOGICAL EXAMINATION OF WATER PWSID# /3 o~7g ) ppm l).,J REPORT TO BE M RESULTS OF EXAMINATION ~b l CJ t.QP ~ ~c>u'tE '576 I 1,j y \ -z.,S 9-a TOT....L COLlFORMS /l00ML OTHER TESTS ABSETN ~~ REMARKS BACTERIA J ML ....T 35-C METHOO OF EXAMIN....TION . INTERPRETATION OF RESULTS PIA 0 MPN 0 MF 0 Colilert ~ REPORTED BY OF A SATISFACTORY SANITARY QUALITY E WAS COLLECTED. THESE RESULTS INDICATE THAT THE WATER IN RESPECT TO THE ABOVE TEST, WHEN ENVIRONMENTAL LABWORKS, INC. BOTTLE NUt.4BER REtE I" ED MAR.. 1 lOOf BACTERIOLOGICAL EXAMINATION OF WATER P.O. Box 733, Marlboro, New York 12542 (845) 236-7823 Fax (845) 236-3911 ELAP 10# 10824 DATE AND TIME RECEIVED 20 2.: 70 el/ TELEPHONE # PRIVATE SUPPLY 0 REPORT TO BE MAIL~O RESULTS OF EXAMINATION \blD \J..::J? ~tt '07b ~'( l2b~O BACT.ER1A I Ml AT 35-C TOTAL COllFORMS /100ML OTHER TESTS REMARKS ABSENT METHOD OF EXAMINATION _ INTERPRETATION OF RESULTS PIA 0 MPN 0 MF 0 Colilert ~ REPORTED BY OF A SATISFAcroRY SANITARY QUALITY WAS COLLECTED. THESE RESULTS INDICA TF. THAT THE WATER IN RESPECT TO mE ABOVE TEST, ATE