Wappingers Emergency Services
Water Systems Operation Report
Microbiological Sample Results
Submitted By: CAMO Pollution Control, Inc.
1610 Route 376
Wappingers Falls, New York 12590
Federal Reporting MonthlYear
Program Code
i Name of Public Water System
Wappingers Emergency Services
Location:
105
TOWN OF WAPPINGER
Source of Supply:
If surface, is filtration provided?
Did an emergency occur in any part of the water system?
Does the system have a disinfection waiver?
I~
I i
Amount of
Treated
Water
Date 1,000 Gals.
l Per Day i
1 1 i 0.24
: 2 t 1.49 i
i 3: i
:---t----l--
,~ I
I ~I ~
7
8
9
10
11
12
13 0.23
! 14~ 0.291
!~T 0.25 I
: 16 1 0.34
I 17 0.74
r- 181
i191
I 20 i
I 21 i
r--n-'
I
I 23
24
25
26
27
[""281
1 29:
r 30 I
1-----1
311
Total
Avg.
Reported by:
Title:
Date:
OCT 07 20;0 ~;''''~
TOWN OF WAPPINGER
TOWN CLERK
CHLORINATION
Gaseous Liquid
Chlorine Hypo-
Used chlorite
Lbs. per Used
24 Hrs. qts
2
8
Free
Chlorine
Residual
mg/l
3.0
3.0
Weight of
Cylinder
Lbs.
pH
0.00
0.32
0.28
0.71
3.0
3.0
2 3.0
4 3.0
2 3.0
3.0
2 3.0
3.0
4 3.0
2 2.8
2 3.0
2 3.0
2 1.5
2 0.5
2 0.3
0.2
2 1.3
1.3
0.30
0.35
0.23
0.26
0.67
0.22
0.28
0.28
0.29
7.77
0.3
38
1.3
I~<I?'((
CAMO Poilu ion cd-htl-blf,=fn~.
47
.4
~l \~~tQ)
Operator
1330192
September
County:
DUTCHESS
I Ground
No
No
No
Population served:
25
Number of required routine samplE
1
Number of actual routine samples
1
Does a M&AR violation exist?
If yes, check reason(s) below:
NO
_ Actual number of samples fewer than required.
_ Failure to analyze for E.coli if there was a
positive result for total coliforms from routine, repeat or
high turbidity (hiturb) sample?
_ Failure to analyze repeat samples.
Does an MCL violation exist?
If yes, check reason(s) below:
NO
_ Two or more positive total coliform samples for
systems collecting fewer than 40 samples (routine, repeat
or hiturb) per month.
_ More than 5% positive total coliform samples for
systems collecting 40 or more samples (routine, repeat or
hiturb) per month.
_ When a positive total Coliform sample is positive
for E.coli and a repeat Total Coliform sample is positive,
OR, when a positive Total Coliform sample is negative for
E.coli, but the repeat Total Coliform sample is positive and
also is positive for E.coli.
* Must collect a minimum of 5 routine samples the month
following a repeat sample collection.
10/-1 /;0
Grade Level:
~ n
\
Cert. No.
,
I
2010 I
IIA
12947
ENVIRONMENTAL LABWORKS, INC.
PO. Box 733, Marlboro, New York 12542
(845) 236-7823
Fax (845) 236-3911
ELAP ID# 10824
RECEIVED SEP 2 2 2010
BOTTlE NUl,4BER
0(/11 -1'1) () 0
BACTERIOLOGICAL EXAMINATION OF WATER
PWS ID# /3,30 J 9 .J
RESULTS FOR LAB USE ONLY
CHLORINE RES. ppm 0 , > .
C.OlLECTED BY
,-) )\1
REPORT TO BE MAILED TO
INTERPRETATION OF RESULTS
absent
COUML A T35-C E.coli/100ML
absent
METHOD OF EXAMINATION
TOTAL COLlFORMS / /
SM199223B 9 17 10
Dale_Time _Analyzed_
THESE RESULTS INDICATF. THAT THE WATER WrI!": OF A SATISFACTORY SANITARY QUALITY
IN RESPECT TO THE ABOVE TEST, WHEN THE SAMPLE WAS AN AL YZED
REPORTEDBY ~- r(.~~ DATE
9/20/1(1)
~