Subject:
Revised Proposed Amendments to Town Buildin~ Code
As requested, we have revised the proposed amendments to the Town of Wappinger
Ordinance for Administering and Enforcing the State Building Construction Code,
otherwise known as the Town Building Code. These amendments pertain to:
. Requiring a foundation survey prior to any further construction, in order to
demonstrate conformance with the approved location and elevation of the
foundation. The proposed amendments now also specify where the foundation
elevation is measured.
. Requiring that the building permit application materials provide enough information
for the Town Building Inspector to determine that the number of bedrooms in
residential structures does not exceed the number imposed by the regulations of the
Dutchess County Department of Health, and that residential structures do not
contain any space which is readily and obviously convertible to one or more
additional bedrooms.
" Requiring a benchmark elevation to be located on each plot of land for the
Building Inspector's use in field checking the elevation of the preparation for the
foundation, prior to the foundation being constructed.
Once these proposed amendments have been finalized, they should be recommended to
the Town Board for formal adoption.
Attachment
David H. Stolman, AICP
Executive Vice President
cc: Supervisor Constance o. Smith
500\wap6-006dkw
Connecticut · (203) 255-3100
FAX. (914) 967-6615
Long Island · (516) 364-4544
November 19, 1997
PROPOSED AMENDMENTS
TO THE
TOWN OF WAPPINGER BUILDING CODE
As presented below, 11_- indicates wording to be added; {braekets Bfla strikeout}
indicate wording to be deleted.
1. Section 10, subparagraph (c) of the Town Building Code would be amended to
read as follows:
li_ii~~~~tl~~~II~~~III.I.~~I_iltii~II:~.!!~~~lil!l\\;I!.:::!\I~B'I~~~gl~:li:~iI_.
[lr\l!~\II!RI!i1i~~i~~___~:::lll!~~II~~~itl~iilll~~:l_~~B~\\I!~~ilt~~i~:_i~\:li
ii1~~i_I*:\~\~I\~~~i\\~i9ilill\~~~_~~~:I~~~e~~~\II_Ii_\\~\i.'i:~::iD{_i'i\~~\\il~\~I!~\~lili!-
_11!f~\IIi.\~.\~lil\\I...1_l\l\._I~ll\~l~:\:I_'f~\ no construction of
any portion of a building other than the construction of a foundation shall
commence until the owner has fIrst submitted to the Building Inspector an "as
built" certifIed plot plan showing the "as built" foundation location fiPil\lmiNil9i
on the plot of land for which the building permit has been issued. Such plan shall
show that such foundation is situated and located within the minimum {sideyardl
setback requirements and shall {indieate 1 .IlB'I that Ii location fiR
1~.9n of the foundation conforms to the "proposed construction" plot plan
'10:..............................................
previously submitted or conforms to variations therefrom previously approved by
the Building Inspector _;~~~li~l~li_\i__ as the result of field inspection.
_l1'!RI!Ri~\lRil!\~._i1~~~i_Ia~\I!i:IIRI!Ri\\\RI~li\\llll\1911\:~li\II::ilii!
lii\:\\.\\I!iKIiIl\\~li~~\.\\\::_~\liil!\~\:lliii~ {The provisions of this subparagraph
shaH only apply to those fooodations which Me situated '.vithin three (3) feet of the
mffiiml::lffi sideyard setbaek requiremeftts I:l3 preseribed l:lftder the zoning ordinanee
or te B:ftY permit i3Sl:led p1:lfSl:laflt to a van8ftee granted tlieretlflder.}
2. Section 8, subparagraph (c) of the Town Building Code would be amended to read
as follows:
( c) Each application for a building permit shall be accompanied by duplicate
copies of plans and specifications, including a plot plan, drawn to scale,
showing the location and size of all proposed new construction and all
existing structures on the site, the nature and character of the work to be
performed and the materials to be incorporated, distance from lot lines, the
relationship of structures on adjoining property, widths and grades of
adjoining streets, walks and alleys, and, where required by the Chief
.Building Inspector, details of structural, mechanical and electrical work,
including computations, stress diagrams and other essential technical data.
.j.':~~ :~~~,.:)jh~q.~~~\, ~~, :,~:~'~~:~f:'-:'~,~;,~;j_', :'.' :"~, ';
.^-,~'.~':i',~~~:~~
..lIll[ii.I_ill\l__lllllll!~lli~\\.illill~I\\\.I~j\lI9[~I[il\[[lillllll.
1_!I\\\l\I\~jl.~l:\II\~\:.l\l\li.!ll::\\lllll._il\l\Il\l\!I!la!i!l\l\lli_1
1_[:[\_~:\iilill[::li\llll._\\llli__[ll[i_:::li_:~II\\\\I.iii!:\\\I~l:\B
Rj:.-~
';;:...gllil~i.!.~lili1_~\[\_lIl\[llil.I[[\\.i~\.iiill\ll_i_ll~l\lI9\\j-
': ,!: ~ ~,,; -.',. ;.;':. ',.
';,..->,:~"~::: <.' :;,'f-
',' \: >'......:...:...< .",;,' ,
.-,', ",',
1!~\ll_\!!!_itiEi!\ill._- Plans and specifications shall bear the
signa!me of the person responsible for the design and drawings. The Chief
Buiiding Inspector may waive the requirement for filing plans.