Loading...
Tall Trees -. Water Systems Operation Report Microbiological Sam pie Results Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 Name of Public Water System Program Code Federal Reporting MonthNear Tall Trees Water 100 1302809 May 2011 Location: TOWN OF WAPPINGER Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? CHLORINATION Amount of Gaseo US Liquid Treated Chlorine Hypo- Free Water Weight of Used chlorite Chlorine Date 1,000 Gals. Cylinder Lbs. per Used Residual pH Per Day Lbs. 24 Hrs. Qts. mg/l 1 19.76 20 1.0 2 17.23 20 1.0 3 14.53 20 1.0 4 19.78 28 1.0 5 13.88 20 1.4 6 15.30 24 1.1 7 17.96 28 1.0 8 23.39 40 1.0 9 15.95 20 1.0 10 18.97 20 1.0 11 15.48 20 1.0 12 21.73 28 1.0 13 13.89 28 0.8 14 15.91 28 1.5 15 17.28 40 1.3 16 17.42 40 1.1 17 18.36 20 1.2 18 20.23 28 0.7 19 15.58 20 0.8 20 19.36 20 0.8 21 19.52 20 1.0 22 20.82 20 1.0 23 2.78 4 1.0 24 22.28 28 0.5 25 25.53 28 1.3 26 16.32 20 1.0 27 25.59 28 1.0 28 36.98 44 1.0 29 20.72 28 0.8 30 25.44 28 1.0 31 19.40 28 1.0 Total 587.37 788 31 Avg. 18.95 25.4 1.0 Reported by: Title: CAMO OllutiOf1=:-~;~~~nR__"::=, lil'; i c=~ \\_r: ! c-J Opera or ., .'u '.. ;..= [Q) JUN 1 i> 2011 GER '--...--- County: DUTCHESS \ Ground \~~ Population served: 251 Number of required routine samplE 1 Number of actual routine samples 1 Does a M&AR violation exist? If yes, check reason(s) below: NO -'! ;.:~ C'"I.) _ Actual number of samples fewer than required. _ Failure to analyze for E.coli if there was a positive result for total coliforms from routine, repeat or high turbidity (hiturb) sampie? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason(s) below: _ Two or more positive total coliform samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total coliform samples for systems collecting 40 or more sampies (routine, repeat or hiturb) per month. _ When a positive total Coliform sample is positive for E.coli and a repeat Total Coliform sample is positive, OR, when a positive Total Coliform sample is negative for E.coli, but the repeat Total Coliform sample is positive and also is positive for E.coli. * Must collect a minimum of 5 routine samples the month following a repeat sample collection. (:ja,~l Grade Level: IIA Cert. No. 12947 . Distribution System Analytical Results Sampling Date of Sample Total Coliform E.coli Free CI- Raw Location Sample Type Positive Positive Residual Turbidity (1,2,3)* mg/L NTU Tower 5/24/11 1 Yes No Yes No 0.8 - - Yes No Yes No Ii,'..... - - - - Yes No Yes No " - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - Yes No Yes No - - - - *1 = Routine sample 2 = Repeat sample 3 = Hiturb sample COMMENTS and/or REMARKS ENVIRONMENTAL LABWORKS, INC. RaTTLE NlJlAilER D(,J~'1l\ 0"1 COllECTED BY ~ J t.: J EXACT co lECTION POINT RECEIVED MAY 3 1 2011 BACTERIOLOGICAL EXAMINATION OF WATER po. Box 733, Marlboro, New York 12542 (845) 236-7823 Fax (845) 236-3911 ELAP ID# 10824 PWS 10# /3o;}. goC; RESULTS FOR LAB USE ONLY CHLORINE RES. ppm-L2J. REPORT TO BE MAILED TO c RESULTS OF EXAMINATION HPC-SM189215B TOTAL COlIFORMS /l00ML ABSENT METHOD OF EXAMINATION TOTAL COLlFORMS SM199223B 5/24 2:30pm Date_Time _Analyzed_ REMARKS COUML AT35-C E.coli/100ML ABSENT B INTERPRETATION OF RESULTS THESE RESULTS INDlCATETHATTHE WATER 1/I7AS OF A SATISFACTORY SANITARY QUALITY IN RESPECT TO THE ABOVE TEST, HEN THE SAMPLE WAS ANALYZED REPORTED BY DATE5/25/2011 ,.