Loading...
Tall Trees Water ; Water Systems Operation Report Microbiological Sam pie Results Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 Name of Public Water System Program Code Federal Reporting MonthNear Tall Trees Water 100 1302809 Decem ber 2p11 Location: TOWN OF WAPPINGER Source of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? CHLORINATION Amount of Gaseous Liquid Treated Chlorine Hypo- Free Water Weight of Used chlorite Chlorine Date 1,000 Gals. Cylinder Lbs. per Used Residual pH Per Day Lbs. 24 Hrs. Qts. mg/l 1 17.42 40 1.0 2 20.77 52 1.0 3 18.72 48 1.0 4 20.51 52 1.2 5 21.34 52 1.0 6 16.56 40 1.1 7 19.09 40 1.1 8 17.20 28 1.0 9 15.64 28 1.0 10 20.70 32 1.0 11 20.74 40 0.7 12 20.51 28 1.0 13 18.24 28 1.0 14 16.90 28 1.0 15 19.05 28 0.8 16 19.83 28 1.0 17 17.25 28 1.0 18 22.79 28 1.0 19 18.98 28 1.0 20 17.25 20 1.0 21 17.43 20 0.8 22 17.63 20 0.8 23 18.83 20 1.0 24 0.47 0 0.8 25 21.89 28 0.6 26 26.37 28 1.0 27 24.12 20 0.8 28 20.74 28 0.8 29 17.89 24 0.8 30 19.47 24 0.8 31 19.94 28 1.0 Total 584.27 936 29 Avg. 18.81 30.2 0.9 Reported by: CAMO Pollution Control, Inc. County: DUTCHESS I Ground I~~ Population served: 251 Number of required routine samplE 1 Number of actual routine samples 1 Does a M&AR violation exist? If yes, check reason(s) below: NO I,.:,' '12::(~')O .? I ' '.' ~.' ,,' ( _ Actual number of samples fewer than required. ;.:t'}1': _ Failure to analyze for E.coli if there was a positive result for total coliforms from routine, repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason(s) ~ tQ) Two or more sitiv~ t~~~~~~C b 0 systems collecting fewe than 40 samples (routine, rrpefll., ': '1 or hiturb) per month. J A i\ 1 ;) , ;: L More than 5% systems collecting 40 or hiturb) per month. .. OWMo~~~~Pl~,~ER ::rsam~dw,~ec , ER,~_ _ When a positive total Coliform sample is positive for E.coli and a repeat Total Coliform sample is positive, OR, when a positive Total Coliform sample is negative for E.coli, but the repeat Total Coliform sample is positive and also is positive for E.coli. " '.; . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Date: ,/ C1 /12 , Grade Level: IIA I~~~~ ., " , Title: Operator Cert. No. 12947 ':, ENVIRONMENTAL LABWORKS, INC. J) BonLE NU"'BER \>>tHol- COlLECTED BY P.O. Box 733, Marlboro, New York 12542 (845) 236-7823 Fax (845) 236-3911 ELAP 10# 10824 REeE I VED DEC 1 3 lOll \ . BACTERIOLOGICAL EXAMINATION OF WATER PRIVATE SUPPLY 0 REPORT TO BE MAILED TO (!,J4ry1() HPC-SM1892158 TOTAL COlIfORMS / 10llML ABSENT COLlML A T35-C E.coli/100ML ABSENT METHOD OF EXAMINATION REMARKS TOTAL COLIFORMS SM1992238 \...... ~ I' Date 1 2/ ~ime 3: 4A>~ed NP .J v INTERPRETATION OF RESUL T5 THESE RESULTS INDICATF. THAT THE WATER WAS OF A SATISFACTORY SANITARY QUALITY IN RESPECT TO THE ABOVE TEST, WHEN THE SAMPLE WAS ANALYZED REPORTED BY -l( ~ ~ DATE 12/12/2011 .J