Loading...
Tall Trees Water Water Systems Operation Report Microbiological Sam pie Results Submitted By: CAMO Pollution Control, Inc. 1610 Route 376 Wappingers Falls, New York 12590 Name of Public Water System Program Code Federal Reporting MonthlYear Tall Trees Water 100 1302809 March 2012 Location: TOWN OF WAPPINGER County: DUTCHESS Sollrce of Supply: If surface, is filtration provided? Did an emergency occur in any part of the water system? Does the system have a disinfection waiver? I Ground I ~~ CHLORINATION Amount of Gaseous Liquid Treated Chlorine Hypo- Free Water Weight of Used chlorite Chlorine Date 1,000 Gals. Cylinder Lbs. per Used Residual pH Per Day Lbs. 24 Hrs. Ots. mg/l 1 19.03 52 0.7 2 18.87 32 0.8 3 19.07 32 1.3 4 14.55 20 1.0 5 9.92 28 1.0 6 19.08 28 1.3 7 18.14 28 1.0 8 18.10 28 1.0 9 16.05 28 1.1 10 12.52 28 1.1 11 20.48 32 1.1 12 39.48 28 0.8 13 17.02 28 0.8 14 17.56 40 1.0 15 18.98 40 1.5 16 18.97 28 1.0 17 21.35 28 1.0 18 20.67 28 1.0 19 18.59 20 1.0 20 18.51 20 0.8 21 19.74 20 1.0 22 21.31 28 0.8 23 17.86 28 0.8 24 19.31 28 1.0 25 28.74 40 1.0 26 12.52 12 1.0 27 19.56 28 0.8 28 20.67 28 1.0 29 19.15 40 1.0 30 21.59 48 1.1 31 8.82 40 1.2 Total 586.21 936 31 Avg. 19.17 29.2 1.0 Population served: 251 Number of requir mp E Number of actual utine s~f ~ ~ ~~~ (Q) Does a M&AR viol tion exist? /SPR J 2 2 J 1 Z If yes, check reas (s) below: , . t j: ~ TOWN Of VV APPINGER _Actual n ber of sT~Y'I~:~Ct~J3J__.~~': _ Failure to analyze for E.coli if there was a positive result for total coliforms from routine, repeat or high turbidity (hiturb) sample? _ Failure to analyze repeat samples. Does an MCL violation exist? NO If yes, check reason(s) below: _ Two or more positive total coliform samples for systems collecting fewer than 40 samples (routine, repeat or hiturb) per month. _ More than 5% positive total coliform samples for systems collecting 40 or more samples (routine, repeat or hiturb) per month. _ When a positive total Coliform sample is positive for E.coli and a repeat Total Coliform sample is positive, OR, when a positive Total Coliform sample is negative for E.coli, but the repeat Total Coliform sample is positive and also is positive for E.coli. . Must collect a minimum of 5 routine samples the month following a repeat sample collection. Reported by: CAMO Pollution Control, Inc. Date:_1/to 1 12- . (f-~~ Grade Level: IIA Title: Operator Cert. No. 12947 ENVIRONMENTAL LABWORKS, INC. P.O. Box 733. Marlboro, New York 12542 (845) 236-7823 Fax (845) 236-3911 ELAP 10# 10824 ~ EeE I YED MAR 1 5 2012 PRIVATE SUPPLVO REPORT TO BE MAIlED TO PWSID# 13o~'?;oC, RESULTS FOR LAB USE ONLY CHLORINE RES. ppm 0 . I BO~E NUIolBER o j Id-.{ J-o s-= COlLECTEO BY __ j).'/ E~LECTION POINT /0 LOe tt.. NAIolE AN();OR LOCATIONS Of WATER SOURCE: ~"" 1- ,-. ~II BACTERIOLOGICAL EXAMINATION OF WATER TELEPHONE # eeS A1-r: (C. HPC-SM1892158 TOTAl COlIFORMS' ,co.tl ABSENT COL/MLAT35-C E.coti/100ML ABSENT METHOD OF EXAMINATION REMARKS TOTAL COLlFORMS SM1992238 Date 3/ 1 t.me 3 pmAnal~fdL_ I 5 ~ c. INTERPRETATION OF RESULTS THESE RESULTS INDlCATF~ THAT THE WATER ~lAS OF A SATISFACTORY SANITARY QUALITY IN RESPECT TO TIlE ABOVE TEST, WHEN TIlE SAMPLE WAS ANALYZED REPORTED BY DATE 3/13/2012